Product overview
HL2P6S-58Ah is an NMC battery module with 2P6S cell configuration. The two available models share the same nominal energy and enclosure dimensions, with different voltage, capacity and current ratings.
Product image is a shared reference for this module range. Electrical specifications are listed below.
Compare the configurations
| Parameter | HL2P6S-58Ah | HL3P4S-58Ah |
|---|---|---|
| Cell configuration | 2P6S (2 parallel × 6 series) | 3P4S (3 parallel × 4 series) |
| Nominal voltage | 22.02 V | 14.68 V |
| Nominal capacity | 116 Ah | 174 Ah |
| Nominal energy | 2.554 kWh | 2.554 kWh |
| Standard charge current | 35 A | 50 A |
| Maximum continuous charge current | 110 A | 170 A |
| Standard discharge current | 58 A | 87 A |
| Maximum continuous discharge current | 116 A | 174 A |
Electrical specifications
| Model | HL2P6S-58Ah |
|---|---|
| Cell chemistry | NMC (nickel manganese cobalt) |
| Cell capacity | 58 Ah |
| Cell configuration | 2P6S |
| Nominal voltage | 22.02 V |
| Nominal capacity | 116 Ah at 1C |
| Nominal energy | 2.554 kWh |
| Working voltage at 0 to 55 °C | 16.5–26.1 V |
| Working voltage at −30 to 0 °C | 13.2–26.1 V |
Charge and discharge limits
| Standard charge current | 35 A |
|---|---|
| Maximum continuous charge current | 110 A |
| Standard discharge current | 58 A |
| Maximum continuous discharge current | 116 A |
| Charge temperature | −20 to 55 °C |
| Discharge temperature | −30 to 55 °C |
Mechanical specifications
| Dimensions (L × W × H) | 355 ± 1 × 151.6 ± 1 × 109.4 ± 1 mm |
|---|---|
| Weight | 12.0 ± 0.3 kg |
Cycle life
| Cycle life | ≥ 1,000 cycles |
|---|---|
| Cycle test conditions | 25 ± 2 °C; 3C charge / 3C discharge; 100% depth of discharge |
Specification conditions
Nominal voltage, capacity, energy and listed current ratings are specified at 25 ± 2 °C. Cycle-life figures apply to the stated laboratory test conditions; use the separate charge and discharge limits for system selection.
System integration
Confirm your system voltage range, BMS, charging requirements, current demand and installation space before choosing a configuration.